You are here: Troubleshooting > Error Codes > Errors 90-99 > Error 92

Error 92: Blade Speed Not Ready

Variable M128

The saw has not detected that the blade started up properly.

What to do now

Hold the STOP button down to stop the saw. Try to restart a second time.

What to do next

  1. If the saw blade has started spinning, check that the blade speed in the monitoring panel is greater than the value set in variable P642.
  2. If there is no reported blade speed while the blade is spinning, stop the saw and check the blade speed sensor located directly behind the saw blade. Confirm that the sensor is secure and has not come loose. Remove the saw blade and confirm that the end of the sensor has not been damaged.
  3. If the blade has not started spinning, check that the hydraulic power pack has started up.